SINAMICS S120: STATIONARY TUNING OF SINAMICS S120



 STATIONARY Tuning of the drive


 Note: Before making any changes please save the original program backup.
  •  Go online with the drive->>load drive unit to PG->> Save.
  • Go offline- >>Project->> Archive->>Norma-l>>S7 program OK->>Save in Computer Hard disk.


Stationary measurement/Tuning

  • Go to SERVO_02->> Commissioning ->> Stationary/Turning Measurement


  • Select Stationary measurement --> Activate measurement
  • After Activation you can see this WARNING message and then close this WARNING dialogue box.
     
  • Enable ASSUME CONTROL PRIORITY Option and Accept the Dialogue box.
·         Give the enable commands and then give ON COMMAND here.

·         After sometime automatically OFF the Machine and you can see the Status No measurement, then New value in the table, after ACCEPT the new values to save the new tuned values to the drive.In some cases you must repeat the measurement.

  •         Copy Ram to ROM for Saving tuning data.
  • Load Drive Unit to PG for saving data in your computer Select Drive->>Target Device->>Load drive Unit to PG

Stationary measurement Summary

1.       SERVO_02->> Commissioning ->> Stationary/Turning Measurement
2.       Select Stationary measurement ->> Activate measurement
3.       Enable ASSUME CONTROL PRIORITY ->>Enable->>ON->>wait for auto drive Off
4.       Accept new values
5.       Copy Ram to ROM
6.       Load Drive Unit to PG
7.       SAVE project







Comments

Popular posts from this blog

SINAMICS G120/ S120: Hardware /Software Change ,Project Upload /Download ,Firmware Upgrade

SINAMICS G120/S120 Hardware /Software Change Project Upload /Download Firmware Upgrade Project Upload/ Download by Starter/ Simotion Scout/BOP The following commissioning tools support the commissioning wizard: STARTER Start drive from V13 SP1 IOP from V1.6 and higher BOP2 If a project is already stored on the CF card, use STARTER to upload it to the PC/PG and make a backup copy if necessary. Upload/Download Procedure with STARTER Inverter → PC/PG To back up the settings with STARTER, proceed as follows: Go online:   Click the "load project to PG/PC" button:   or Target Device>> load project to PG/PC button Wait until STARTER reports that data backup has been completed. Save the project: Go offline:    Click Project >>Archive Button. PC/PG → Inverter Normally this option use when you have changes settings offline or you have old project. To load the settings from the PG to th...

Sinamics S120: HOMING(Absolute Encoder Adjustment)

Homing HOMING (Absolute Encoder Adjustment) Note: Doing this process will make your actual position as home position make sure your machine is at home position or beware of mechanical position. ·          Select SERVO_02 -> Technology -> Basic Positioner --> Homing -> Homing/configuration (right side window) -> Homing. ·          Before doing homing your actual value will be different. ·          Click Perform absolute value calibration (Before doing this make machine position in home position, then make homing) ·          After done Homing, it will ask to save the value (Copy RAM TO ROM). And actual value will go 0 value. ·          You can see this when doing RAM TO ROM option. Saving all the data in the Permanent memory. ·    ...

SINAMICS S210: Reset parameters, the safety parameters und the Webserver passwords

SINAMICS S210: Reset parameters, the safety parameters und the Webserver passwords In order to erase the complete parameterization including the Safety parameterization and the Webserver passwords please proceed as follows: Create a file with the name “updater.inf” containing the text “UPDATE_FORMAT_RW 0 1” or download the file from Siemens website. updater.zip (1 KB)  Copy the file “updater.inf” onto an empty SD-Card (max. 2GB, e.g. 6SL3054-4AG00-2AA0). Turn the converter off and insert the SD-Card into the card slot of the converter. Turn the converter back on and wait until the startup of the converter has completed (RDY LED permanently green). Turn the converter off and remove the SD-Card*. Turn the converter back on and perform a new parameterization of the converter – if required – including Safety parameterization and acceptance test. Reset the  Web server passwords,  parameters&  safety parameters ...